The same digest on 16 machines, from CPU, SIMD and GPU
One integer program, a ternary matrix-vector product on one fixed input, returned the same digest from the plain CPU loop, the SIMD loop and the GPU shader on each of 16 machines. Two more integer programs in each machine's run also matched on every machine: a 1,024-bit associative-memory search, on all three fabrics, and a 1-bit matrix product, on the CPU loop and the GPU only.
- Runs
- One run on each of 16 machines.
- How
- Each run hashes each fabric's output with BLAKE3 and compares the digests. The machines run three operating systems on two processor architectures, with three SIMD instruction sets and eleven different GPU and driver combinations under three graphics interfaces.
- Where it stops
-
- Integer arithmetic only. The programs use no floating point, so the check shows that each compiler, driver and link carries exact integers, not that floating-point results agree.
- One fixed input per program, not a sweep of edge cases.
- A run whose fabrics disagree stops and writes no record, so the 16 records hold agreements only. The fault run in the next fact is what shows a difference is caught.
- The 16 machines are the company's own machines, not ones chosen from outside the company.